bg texture 2
Rentals

Hunter Rentals:
Blast-Resistant Buildings for Hire

Hunter rentals are ideal for operations requiring industry-leading blast protection on a temporary basis, or for projects with fast turnaround times. With Hunter locations across multiple continents, careful consideration of international building codes and installation assistance available, too, you have access to safe buildings for rent, no matter where a project takes you.

Hunter Leasing Locations Include:

03 00 Rentals Building
03 00 Rentals 1

Stress-Free Structures
Available worldwide

Trust that Hunter Leasing affords you a custom-tailored experience that serves every aspect of your operations. Our global sales team meets with you to discuss your unique project, timeline and budgetary constraints, and any special considerations required. From there, we’ll pinpoint the structure and lease terms required to meet project expectations. With short- and long-term Hunter leasing options available, the ability to serve projects of sizes and scopes — and to serve customers in most languages and all time zones, too — we’re here to keep your operations on safer footing.

Hunter Leasing Locations Include:

Discounts Available for Leases of 12+ Months


A Full Range of Available Floorplans

Hunter offers a number of blast-resistant and modular buildings for rent, with versatile floorplans to accommodate companies’ needs.

A Region-by-Region Look at Hunter Prefab Lease Building Options

03 00 Rentals US

United States Rentals Through Hunter Onsite

  • Certified Standard Blast Rating of 8 PSI (550 mbar) Free Field VCE Pressures
  • Duration of 200 Msec
  • Built in Accordance with ASCE 2010 Publication “Design of Blast-Resistant Buildings in Petrochemical Facilities”, Second Edition
  • API RP 752/753/756 Compliant
  • Single & Multi-Unit Complexes Available
    • Single Module Dimensions: 12’ (W) x 40’ (L) x 11’ 9” (H)
    • Two-Module Complex Dimensions: 24’ (W) x 40’ (L) x 11’ 9” (H)
    • Mechanically Fastened On-Site (Two 12’ (W)) Modules Shipped Separately)
    • Dimensions are Nominal
  • Phone & Internet Connectivity
  • Two Blast-Resistant Doors Per Building
  • Smoke/CO2 Detector
  • Insulation: Roof=R-27.2, Floor=R-25.2, Exterior Walls=R-19
  • Gypsum Sub-Ceiling
  • Class I Division 2 External Electrical
  • Class I Division 2 Thermostatically Controlled HVAC
  • Low Leakage “Safe Haven” Dampers

Ready to Rent in the U.S.?

Contact Partner Company Hunter Onsite to Get Started
281.501.7775 | Email

HUNT OnSitelogo

03 00 Rentals EU

Europe Rentals/Hires

  • Certified Standard Blast Rating of 5 PSI (300 mbar) & 8 PSI (550 mbar) Free Field
  • Duration of 200 Msec
  • Rated for 8 PSI (550 mbar) 200 Msec Medium Damage, ATEX Zone 1 & 2 
  • Built in Accordance with ASCE 2010 Publication “Design of Blast-Resistant Buildings in Petrochemical Facilities”, Second Edition
  • API RP 752/753/756 Compliant
  • Hunter Provides the Best Suitable Design with Door & Window Setup, Based on Fleet Availability
  • Module Sizes Available
    • Type A (Single Unit): 6m (L) x 3m(W) x 3m (H)
    • Type B (w/ open side wall at one length): 6m (L) x 3m(W) x 3m (H)
    • Type D (w/ open side wall at both lengths): 6m (L) x 3m(W) x 3m (H)
  • Modules Can be Used Stand-Alone or in a Complex for Flexible Layout Design
  • Complexes of Two, Three, Four and Five Units Can be Created
  • Single Units are Outfitted with HVAC, while Multi-Unit Complexes Feature Multiple HVAC Units
  • Phone & Internet Connectivity
  • Furniture Rental Available
  • Fire Detection/Protection
  • Insulation: 40 kg/m3, 200 m in Roof, 150 mm in Floor & 90 mm in Walls
  • Gypsum Sub-Ceiling & Seismic Standard Suspended Ceiling
  • No Extra Foundation Needed
  • Full-Service Installation Available
  • All Electrical Indoor Lighting and Small Power Devices Located Inside and Outside the BRM are Suitable for Safe Area Operation
  • Power Distribution 240V/415V 50HZ
  • Switch-controlled Lighting
  • Receptacles Located on the Interior Perimeter Wall
  • All Switches and Receptacles to be Recessed
  • Indoor Lighting Shall Consist of:
    • Ceiling-mounted Indoor Lights, 2x36W
    • Emergency Backup Lighting
    • Emergency & Exit Lighting
    • EMT/GI Conduits, Internal CAT 6 Cables, RJ45 Faceplates
  • European Fleet Stationed in the Netherlands & Ready for Deployment throughout Europe 
  • Full Staging & Operational Centers throughout Europe, Allowing for Faster Delivery & Reduced Transportation Costs
  • Full Complement of Services & Personnel in Each Country of Operation
  • Full-Service Installation Available
  • Lease Modules Serviced & Transported/Installed by Hunter European Operations

Ready to Hire a Building in Europe?


03 00 Rentals UK

United Kingdom Rentals/Hires

  • Certified Standard Blast Rating of 5 PSI (300 mbar) & 8 PSI (550 mbar) Free Field
  • Duration of 200 Msec
  • Rated for 8 PSI (550 mbar) 200 Msec Medium Damage, ATEX Zone 1 & 2 
  • Built in Accordance with ASCE 2010 Publication “Design of Blast-Resistant Buildings in Petrochemical Facilities”, Second Edition
  • API RP 752/753/756 Compliant
  • 32-foot, 100 mbar Units Available Exclusively in the United Kingdom
  • Hunter Provides the Best Suitable Design with Door & Window Setup, Based on Fleet Availability
  • Module Sizes Available
    • Type A (Single Unit): 6m (L) x 3m(W) x 3m (H)
    • Type B (w/ open side wall at one length): 6m (L) x 3m(W) x 3m (H)
    • Type D (w/ open side wall at both lengths): 6m (L) x 3m(W) x 3m (H)
  • Modules Can be Used Stand-Alone or in a Complex for Flexible Layout Design
  • Complexes of Two, Three, Four and Five Units Can be Created
  • Single Units are Outfitted with HVAC, while Multi-Unit Complexes Feature Multiple HVAC Units
  • Phone & Internet Connectivity
  • Furniture Rental Available
  • Fire Detection/Protection
  • Insulation: 40 kg/m3, 200 m in Roof, 150 mm in Floor & 90 mm in Walls
  • Gypsum Sub-Ceiling & Seismic Standard Suspended Ceiling
  • No Extra Foundation Needed
  • Full-Service Installation Available
  • All Electrical Indoor Lighting and Small Power Devices Located Inside and Outside the BRM are Suitable for Safe Area Operation
  • Power Distribution 240V/415V 50HZ
  • Switch-controlled Lighting
  • Receptacles Located on the Interior Perimeter Wall
  • All Switches and Receptacles to be Recessed
  • Indoor Lighting Shall Consist of:
    • Ceiling-mounted Indoor Lights, 2x36W
    • Emergency Backup Lighting
    • Emergency & Exit Lighting
    • EMT/GI Conduits, Internal CAT 6 Cables, RJ45 Faceplates
  • UK Fleet Stationed in the Teesside, North East England & Ready for Deployment throughout the United Kingdom
  • Full Complement of Services & Personnel in Each Country of Operation
  • Full-Service Installation Available
  • Lease Modules Serviced & Transported/Installed by Hunter European Operations

Ready to Hire a Building in the United Kingdom?


03 00 Rentals ME

Middle East Rentals — Based in the GCC

  • Certified Standard Blast Rating of 5 PSI (300 mbar), 8 PSI (550 mbar) & 10 PSI (689 mbar) Free Field
  • Duration of 200 Msec
  • Built in Accordance with ASCE 2010 Publication “Design of Blast-Resistant Buildings in Petrochemical Facilities”, Second Edition
  • API RP 752/753/756 Compliant
  • Single & Multi-Unit Complexes Available
    • Single Module Dimensions: 12 m (L) x 3 m (W) x 3 m (H)
    • Two-Module Complex Dimensions: 12 m (L) x 4.8 m (W) x 3 m (H)
    • Mechanically Fastened On-Site (Two 2.4 m (W) Modules Shipped Separately)
  • Phone & Internet Connectivity
  • Two (2) Blast-Resistant Doors Per Building
  • Fire Detection/Protection
  • Insulation: 40 kg/m3, 200 m in Roof, 150 mm in Floor & 90 mm in Walls
  • Gypsum Sub-Ceiling & Seismic Standard Suspended Ceiling
  • Class I Division 2 External Electrical
  • Class I Division 2 Thermostatically Controlled HVAC
  • Low Leakage “Safe Haven” Dampers
  • Manufacturing & Main Leasing Operations in the Middle East for Delivery throughout the GCC Region
  • Full Complement of Services & Personnel in Each Country of Operation
  • Full-Service Installation Available

Ready to Hire a Building in the Middle East?

Contact us to learn more
about Hunter Rentals

Name(Required)
✓ Valid number ✕ Invalid number
Lease Terms:
This field is for validation purposes and should be left unchanged.

03 00 Rentals CustomCTA BG

Need a Structure that’s
Built to Suit?

Learn more about Hunter custom buildings